show the entry list
Multi Panel -- Product information -- Technical data and ordering information
Which PROFINET services are supported by SIMATIC panels.
What support does Siemens AG offer to make use of WinCC flexible, WinCC flexible Runtime and panels that can be configured with WinCC flexible comply with FDA regulations?
What support does Siemens AG offer to make use of WinCC Runtime Advanced, WinCC Runtime Professional and panels that can be configured with WinCC (TIA Portal) comply with FDA regulations?
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
Which panels are certified for the FM explosion protection standard for North America?
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
Which panels and flat screens does Siemens currently offer for hazardous areas with potentially explosive atmosphere (Ex2/22)?
Wich protective films can I use with SIMATIC HMI panels?
How can you determine the "E-Stand" (hardware release) of an operator panel?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
The C7 6xx complete devices are to be discontinued in October 2010 – what are their successors?
Which panels does Siemens currently offer with stainless steel fronts (INOX)?
What support does Siemens AG offer to make products comply with FDA regulations?
What are the order numbers for the backup batteries and accumulators for the operator panels?
Which panels are certified for shipbuilding?
How do you replace a faulty operator panel, or where can I have a faulty device repaired?
Different sized projects for MP270 devices
Which protective covers are available for panels?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Which SIMATIC Panels have the CCC certificate?
Which Siemens department holds the EC conformity declarations for SIMATIC HMI?
Basic Panels -- Product information -- Technical data and ordering information
What support does Siemens AG offer to make use of WinCC flexible, WinCC flexible Runtime and panels that can be configured with WinCC flexible comply with FDA regulations?
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
Which SIMATIC Panels have the CCC certificate?
Wich protective films can I use with SIMATIC HMI panels?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
How can you determine the "E-Stand" (hardware release) of an operator panel?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
What connections are there between the version designations in WinCC flexible?
Which PROFINET services are supported by SIMATIC panels.
What are the functional differences between the different SIMATIC panels?
Why is an Open Source CD supplied with the operator panel?
What support does Siemens AG offer to make products comply with FDA regulations?
What support does Siemens AG offer to make use of WinCC Runtime Advanced, WinCC Runtime Professional and panels that can be configured with WinCC (TIA Portal) comply with FDA regulations?
Which panels are certified for shipbuilding?
What should you watch out with regard to licenses for WinCC flexible and panels?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Which Siemens department holds the EC conformity declarations for SIMATIC HMI?
Touch Panel / Operator Panel -- Product information -- Technical data and ordering information
What support does Siemens AG offer to make use of WinCC flexible, WinCC flexible Runtime and panels that can be configured with WinCC flexible comply with FDA regulations?
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
Which SIMATIC Panels have the CCC certificate?
Wich protective films can I use with SIMATIC HMI panels?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
How can you determine the "E-Stand" (hardware release) of an operator panel?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
Which PROFINET services are supported by SIMATIC panels.
Which panels and flat screens does Siemens currently offer for hazardous areas with potentially explosive atmosphere (Ex2/22)?
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
Why is an Open Source CD supplied with the operator panel?
Which panels does Siemens currently offer with stainless steel fronts (INOX)?
What support does Siemens AG offer to make products comply with FDA regulations?
What support does Siemens AG offer to make use of WinCC Runtime Advanced, WinCC Runtime Professional and panels that can be configured with WinCC (TIA Portal) comply with FDA regulations?
What are the order numbers for the backup batteries and accumulators for the operator panels?
Which panels are certified for shipbuilding?
Which panels are certified for the FM explosion protection standard for North America?
Which protective covers are available for panels?
Which Siemens department holds the EC conformity declarations for SIMATIC HMI?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Mobile Panels -- Product information -- Technical data and ordering information
What support does Siemens AG offer to make use of WinCC flexible, WinCC flexible Runtime and panels that can be configured with WinCC flexible comply with FDA regulations?
Wich protective films can I use with SIMATIC HMI panels?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
What should you watch out for when connecting the equipotential bonding to the connection box of a mobile panel?
How can you determine the "E-Stand" (hardware release) of an operator panel?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
Which PROFINET services are supported by SIMATIC panels.
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
What support does Siemens AG offer to make use of WinCC Runtime Advanced, WinCC Runtime Professional and panels that can be configured with WinCC (TIA Portal) comply with FDA regulations?
Which panels are certified for shipbuilding?
What should you watch out with regard to licenses for WinCC flexible and panels?
How do you incorporate the execution times of the F blocks for the Mobile Panel 277F IWLAN into the "S7fcotia.xls" table?
Which installation guidelines do you have to watch out for with the transponders for the Mobile Panel 227 IWLAN and the Mobile Panel 277F IWLAN?
Mobile Panel 170 can only be used with the connection box
Which Siemens department holds the EC conformity declarations for SIMATIC HMI?
Which SIMATIC Panels have the CCC certificate?
Which SIMATIC panels have or need an FCC certificate?
Why is there no yellow-and-red emergency stop button on the tethered-connection mobile panel?
No standard project in WinCE devices
Comfort Panels -- Product information -- Technical data and ordering information
What support does Siemens AG offer to make products comply with FDA regulations?
What support does Siemens AG offer to make use of WinCC Runtime Advanced, WinCC Runtime Professional and panels that can be configured with WinCC (TIA Portal) comply with FDA regulations?
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
Which panels are certified for shipbuilding?
Which panels are certified for the FM explosion protection standard for North America?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
Which PROFINET services are supported by SIMATIC panels.
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
Which SIMATIC Panels have the CCC certificate?
Thin Client -- Product information -- Technical data and ordering information
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
Which PROFINET services are supported by SIMATIC panels.
Wich protective films can I use with SIMATIC HMI panels?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
What cost-effective options do Thin Clients provide as operator panels in a plant?
Which Siemens department holds the EC conformity declarations for SIMATIC HMI?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
Part number:

Description
The table below gives you an overview of the power consumption of various SIMATIC HMI operator panels.

Explanation of the calculation
With SIMATIC HMI operator panels the power dissipation is only insignificantly less than the power consumption. The values listed below for power consumption are therefore almost identical to the maximum and minimum power dissipation.
Note that these values change when IO devices (a USB mouse, for example) are connected to the operator panel. Please refer to the relevant device manuals for the power consumption of the various interfaces and the permissible range of the rated voltage.
  
SIMATIC HMI Operator Panels
(Comfort Panels)

Power consumption in watt

Min. Max.
KP400 Comfort 2,5 3,7
KPT400 Comfort 2,5 3,7
TP700 Comfort 9,6 14,4
KP700 Comfort 9,6 14,4
TP900 Comfort 14,4 21,6
KP900 Comfort 14,4 21,6
TP1200 Comfort 16,3 24,5
KP1200 Comfort 16,3 24,5
TP1500 Comfort 28,8 43,2
KP1500 Comfort 28,8 43,2
TP1900 Comfort 25 37,5
TP2200 Comfort 42,3 63,4
Table 01

 
SIMATIC HMI Operator Panels
(Basic Panels)

Power consumption in watt

Min. Max.
KP300 Basic mono PN 1,9 2,8
KP400 Basic color PN 1,9 2,8
KTP400 Basic mono PN 1,9 2,8
KTP400 Basic color PN 1,9 2,8
KTP600 Basic mono PN 5,8 8,4
KTP600 Basic color DP/PN 8,4 13,2
KTP1000 Basic color DP/PN 14,4 24
TP1500 Basic color PN 19,2 24
Table 02

 
SIMATIC HMI Operator Panels
(Micro Panels)

Power consumption in watt

Min. Max.
OP 73micro 1,9 5
OP 177micro 5,8 7,2
Table 03

 
SIMATIC HMI Operator Panels
(Panels)

Power consumption in watt

Min. Max.
OP 73 1,9 5
OP 77A 4,8 7,2
OP 77B 4,8 7,2
TP 177A 7,2 10,8
TP 177B 4" Widescreen 4,8 13,2
TP 177B 7,2 12
OP 177B 7,2 12
TP 277  16,1 17,8
OP 277 16,1 17,8
Table 04

 
SIMATIC HMI Operator Panels
(Multi Panels)

Power consumption in watt

Min. Max.
MP 177 16,1 17,8
MP 277 8" Touch 14,4 24
MP 277 10" Touch 16,8 26,4
MP 277 8" Key 16,8 26,4
MP 277 10" Key 19,2 28,8
MP 377 12" Touch 31,2 43,2
MP 377 12" Key 31,2 43,2
MP 377 15" Touch 40,8 60
MP 377 PRO 15" Touch 40,8 60
MP 377 15" Touch daylight readable 36 67,2
MP 377 19" Touch 52,8 74,4
Table 05

 
SIMATIC HMI Operator Panels
(Mobile Panels)
Power consumption in watt
Min. Max.
Mobile Panel 177 DP connection box 7,1 10,1
Mobile Panel 177 PN connection box 9,2 13
Mobile Panel 277 DP connection box 12,2 17,3
Mobile Panel 277 PN connection box 12,2 17,3
Mobile Panel 277 IWLAN 28,8 43,2
Mobile Panel 277 IWLAN incl. main battery in charging bays 53,8 80,6
Mobile Panel 277F IWLAN 28,8 43,2
Mobile Panel 277F IWLAN incl. main battery in charging bays 53,8 80,6
DP connection box without Mobile Panel   2,4 2,9
PN connection box without Mobile Panel   2,4 2,9
Table 06  

 
SIMATIC HMI Operator Panels
(Thin Client)

Power consumption in watt

Min. Max.
Thin Client 10" Touch (4:3) 12 26,4
Thin Client 15" Touch (4:3) 16,8 26,4
Thin Client PRO 15" (4:3) 16,8 26,4
SIMATIC ITC 1200 (Widescreen) 19,2 28,8
SIMATIC ITC 1500 (Widescreen) 28,8 43,2
SIMATIC ITC 1900 (Widescreen) 25 37,4
SIMATIC ITC 2200 (Widescreen) 42,2 63,4
Table 07

Note
The values listed are valid subject to changes in the course of technical developments.

Additional Keywords
Current, Power consumption, Voltage

 Entry ID:44356678   Date:2013-09-30 
I regard this article....as helpfulas not helpful                                 
mySupport
My Documentation Manager 
Newsletter 
CAx-Download-Manager 
Support Request
To this entry
Print
Create PDF 
Send to a friend
QuickLinks
Compatibility tool 
Help
Online Help
Guided Tour