Which modules can you use when implementing software redundancy? 
Which SIMATIC S7 modules support the "Direct Data Exchange" function (internode communication)? 
Cables for S7-400 interface modules (IM 46x) in standard lengths and special lengths 
Supplements on Hardware Configuration of CiR 

Which modules can you use when implementing software redundancy?Go to beginning
Part number:

Description
Software Redundancy (SWR) is a software package for configuring fault-tolerant controllers with standard components. The controller part consists of standard CPUs of the S7-300 and S7-400 series. The redundancy link for synchronizing the redundant CPUs is achieved with standard communication mechanisms like CPs or via an MPI interface. Connection to I/O devices is via two redundant PROFIBUS DP segments to the ET-200M stations with redundant IM 153-2 interface modules. You can also implement Software Redundancy on WinAC RTX as from version 2008.

Note
More information is available in the function manual "Software Redundancy for SIMATIC S7" in Entry ID 1137637.

The following table lists modules that support software redundancy. The lowercase letter x is a wildcard character in the order numbers.

S7-300 CPUs
 
Module Order number
CPU 313C-2 DP 6ES7313-6CE0x-0AB0
6ES7313-6CF03-0AB0
6ES7313-6CG04-0AB0
CPU 314C-2 DP 6ES7314-6CF0x-0AB0
6ES7314-6CG0x-0AB0
6ES7314-6EH04-0AB0
CPU 315-2 DP 6ES7315-2AFxx-0AB0
6ES7315-2AG10-0AB0
6ES7315-2AH14-0AB0
CPU 315F-2 DP 6ES7315-6FF0x-0AB0
CPU 315-2 PN/DP 6ES7315-2EG10-0AB0
6ES7315-2EH1x-0AB0
CPU 315F-2 PN/DP 6ES7315-2FH1x-0AB0
6ES7315-2FJ14-0AB0
CPU 315T-2 DP 6ES7315-6Tx1x-0AB0
CPU 316-2 DP 6ES7316-2AG0x-0AB0
CPU 317-2 DP 6ES7317-2AJ10-0AB0
6ES7317-2AK14-0AB0
CPU 317F-2 DP 6ES7317-6FF0x-0AB0
CPU 317-2 PN/DP 6ES7317-2Ex1x-0AB0
CPU 317F-2 PN/DP 6ES7317-2Fx1x-0AB0
CPU 317T-2 DP 6ES7317-6Tx1x-0AB0
CPU 318-2 DP 6ES7318-2AJ0x-0AB0
CPU 319-3 PN/DP 6ES7318-3EL0x-0AB0
CPU 319F-3 PN/DP 6ES7318-3FL0x-0AB0
Table 01

S7-400 CPUs
 
Module Order number
CPU 412-1 6ES7412-1XF0x-0AB0
6ES7412-1XJ05-0AB0
CPU 412-2 PN 6ES7412-2EK06-0AB0
CPU 412-2 6ES7412-2XG0x-0AB0
6ES7412-2XJ05-0AB0
CPU 413-1 6ES7413-1XG0x-0AB0
CPU 413-2 6ES7413-2XG0x-0AB0
CPU 414-1 6ES7414-1XG0x-0AB0
CPU 414-2 6ES7414-2XG0x-0AB0
6ES7414-2XJ0x-0AB0
6ES7414-2XK05-0AB0
CPU 414-3 6ES7414-3XJ0x-0AB0
6ES7414-3XM05-0AB0
CPU 414-3 PN/DP 6ES7414-3EM05-0AB0
6ES7414-3EM06-0AB0
CPU 414F-3 PN/DP 6ES7414-3FM06-0AB0
CPU 416-1 6ES7416-1XJ0x-0AB0
CPU 416-2 6ES7416-2XK0x-0AB0
6ES7416-2XL0x-0AB0
6ES7416-2XN05-0AB0
CPU 416F-2 6ES7416-2FN05-0AB0
CPU 416-3 6ES7416-3XL0x-0AB0
6ES7416-3XR05-0AB0
CPU 416-3 PN/DP 6ES7416-3ES06-0AB0
6ES7416-3ER05-0AB0
CPU 416F-3 PN/DP 6ES7416-3FR05-0AB0
6ES7416-3FR06-0AB0
CPU 417-4 6ES7417-4XL0x-0AB0
6ES7417-4XT05-0AB0
Table 02

Note
The SIMATIC S7-300/400 F-CPUs are to be used here without F program.

Communication modules with DP master function
 
Module Order number
CP 443-5 EXT
(connection to PROFIBUS network)
6GK7443-5DX04-0XE0
6GK7443-5DX05-0XE0
IM 467 and IM 467-FO
(can only be used in version V1.1)
6ES7467-5GJ0x-0AB0
6ES7467-5FJ00-0AB0
Table 03

Communication modules for linking the stations
 
Module Order number
CP 342-5 6GK7342-5DA00-0XE0
6GK7342-5DA02-0XE0
6GK7342-5DA03-0XE0
CP 343-1 6GK7343-1BA00-0XE0
6GK7343-1EX11-0XE0
6GK7343-1EX30-0XE0
6GK7343-1GX30-0XE0
CP 343-1 LEAN
(connection to Industrial Ethernet)
6GK7343-1CX10-0XE0
CP 443-5 EXT
(connection to PROFIBUS network)
6GK7443-5DX04-0XE0
6GK7443-5DX05-0XE0
CP 443-1 ISO1
(connection to Industrial Ethernet)
6GK7443-1EXxx-0XE0
6GK7443-1GXxx-0XE0
6GK7443-1BXxx-0XE0
Table 04

Modules for distributed I/O device ET 200M
 
Module Order number
IM 153-2 6ES7153-2BA0x-0XB0 as from release 2
(bus module 6ES7195-7HD10-0XA0)
FM 350-1 6ES7350-1AH0x-0AE0
CP 341
(20 mA TTY, RS232, RS422/485)
6ES7341-1xH01-0AE0
6ES7341-1xH02-0AE0
CP 341
(RS232C)
6ES7341-1AH02-0AE0
All digital and analog modules for ET 200M (see Catalog ST70)
Table 05

PC-based controller
 
Module Order number
Windows Logic Controller WinAC RTX F V4 6ES7611-4FB00-0YB7
You cannot order this MLFB separately but only as part of the products below.
  • WinAC RTX F as from version 2009 (6ES7 671-1RC0x-0YA0)
  • SIMATIC IPC427 Bundles (6ES7 675-1D...)
  • SIMATIC HMI IPC477C Bundles(6AV7 884-...)
Windows Logic Controller WinAC RTX V4 6ES7611-4SB00-0YB7
You cannot order this MLFB separately but only as part of the products below.
  • WinAC RTX as from version 4 (6ES7 671-0RC0x-0YA0)
  • Microbox 420-RTX (6ES7 675-1B...)
  • Microbox 427B Bundles (6ES7 675-1C...)
  • IPC427C Bundles (6ES7 675-1D...)
  • Panel PC 477 HMI/RTX (6AV7 84...)
  • Panel PC 477B Bundles (6AV7 85...)
  • HMI IPC477C Bundles (6AV7 884...)
Embedded Controller, EC31 6ES7677-1DD00-0BA0
6ES7677-1DD10-0BA0
Embedded Controller, EC31-RTX 6ES7677-1DD00-0BB0
6ES7677-1DD10-0BB0
Embedded Controller, EC31 HMI/RTX 6ES7677-1DD00-0BF0
6ES7677-1DD00-0BG0
6ES7677-1DD00-0BH0
6ES7677-1DD10-0BF0
6ES7677-1DD10-0BG0
6ES7677-1DD10-0BH0
Embedded Controller, EC31-RTX F 6ES7677-1FD00-0FB0
6ES7677-1FD10-0FB0
Table 06  

Note
The ET 200M stations must always be configured with active bus modules (6ES7195-7HB00-0XA0 or 6ES7195-7HC00-0XA0), even if the "Hot swapping of I/O modules" function is not possible with S7-300 CPUs.

Which SIMATIC S7 modules support the "Direct Data Exchange" function (internode communication)?Go to beginning
Part number:

Configuration Notes:
The following table gives you an overview of the SIMATIC S7 modules that support the "Direct Data Exchange" function (internode communication) as I slave or DP master in the receive and send area.
 
Module I slave DP master
S7-300 CPUs x x
S7-400 CPUs x1) x1)
ET200 CPUs    
BM147-1 CPU x x
BM147-2 CPU x x
IM151-7 CPU x x
IM151-7 CPU FO x x
IM151-7 F-CPU x x
IM154-8 CPU x x
PROFIBUS CPs    
CP342-5 - -
CP443-5 EXT - x
S7-400 IM modules    
IM 467 - x
IM 467 FO - x
WinAC RTX 2005 from SP2 - x
 x1) The "Direct Data Exchange" function is supported in Send mode from V3.0 and from in Receive mode from V1.1.

Note:
When implementing interface modules, support of the "Direct Data Exchange" (internode communication) function depends on the CPU used and not on the interface module itself.

Cables for S7-400 interface modules (IM 46x) in standard lengths and special lengthsGo to beginning
Part number:


 

QUESTION:
Where can I get information about ordering and using cables for the S7-400 interface modules (IM 46x)?

ANSWER:
The following table shows the standard cable lengths (in order of length):

Cable length
(in meters)

Description

MLFB

0.75

SIMATIC S7-400, IM cable with K bus

6ES7 468-1AH50-0AA0

0.75

SIMATIC S7-400, IM cable with SV bus without K bus

6ES7 468-3AH50-0AA0

1.5

SIMATIC S7-400, IM cable with K bus

6ES7 468-1BB50-0AA0

1.5

SIMATIC S7-400, IM cable with SV bus without K bus

6ES7 468-3BB50-0AA0

5

SIMATIC S7-400, IM cable with K bus

6ES7 468-1BF00-0AA0

10

SIMATIC S7-400, IM cable with K bus

6ES7 468-1CB00-0AA0

25

SIMATIC S7-400, IM cable with K bus

6ES7 468-1CC50-0AA0

50

SIMATIC S7-400, IM cable with K bus

6ES7 468-1CF00-0AA0

100

SIMATIC S7-400, IM cable with K bus

6ES7 468-1DB00-0AA0

250

SIMATIC S7-400, IM cable

6ES7 468-1DC50-0AA0

450

SIMATIC S7-400, IM cable

6ES7 468-1DE50-0AA0

600

SIMATIC S7-400, IM cable

6ES7 468-1DG00-0AA0

Table 1: Overview of standard cable lengths

Please note the following when ordering special cable lengths for the S7-400 interface modules:

  • Order number / MLFB
    Length code for connecting cables with MLFB No.: 6ES7 468-1XYZ0-0AA0

Notes on the letters X, Y and Z in the order number / MLFB:

Characteristics of "X":

Code letter

Unit of measurement

Range

Grading

Tolerance

Number

Length

B

cm

100 - 990

100cm - 990cm

10 cm

+30cm

C

dm

100 - 990

100dm - 990dm

10 dm

+0.5m

D

m

100 - 600

100m - 600m

10 m

+1m

Table 2: Characteristics of "X"

Characteristics of "Y":

Code letter

A

B

C

D

E

F

G

H

J

K

Number

-

1

2

3

4

5

6

7

8

9

Table 3: Characteristics of "Y"

Characteristics of "Z":

For the letter "Z" in order number / MLFB please specify a number from 0 to 9 for the special length of your cable.

Examples:
MLFB No.: 6ES7468-1BJ60-0AA0 calculation for 860cm cable: B:100cm, J:8 -> 100cm * 8 + 60
MLFB No.: 6ES7468-1CE90-0AA0 calculation for 490dm cable: C:100dm, E:4 -> 100dm * 4 + 90
MLFB No. 6ES7468-1DB50-0AA0 calculation for 150m cable: D:100m, B:1 -> 100m * 1 + 50

  • Costs:
    A surcharge of 10% on the cable price will be levied for cable lengths of 150m and more. A processing charge of EUR 60 per order item will also levied.
  • Delivery times:
    For special cable lengths: up to 14 weeks

Cables in special lengths that are not in the standard program, can be ordered separately. Please get in touch with your regional SIMATIC sales representative for this.

Note for SIMATIC sales staff:
More information is available in Entry ID 7831922.

Important:
Joining two or more cables together is not permitted. The functioning of the connection can in such cases no longer be ensured because of the reflections produced.

Keywords:
Hardware compatibility, System accessories, IM, Cable, Extension device



Supplements on Hardware Configuration of CiRGo to beginning
Part number:

QUESTION:
Which hardware configuration is there for CiR?

ANSWER:
In manual "Plant modification during operation via CiR" (Entry-ID: 14044916) are given the hardware configuration in Chapter 1.

In addition to this there are restrictions for MAP-CP 444 (Order No. 6ES7444-1MX00-0XE0) 
and the 
DP master interface module IM467 (Order No. 6ES7467-5FJ00-0AB0 and 6ES7467-5GJ0x-0AB0).

The use of these modules within a station, on which you want to make modification via CiR during operation, is not possible.


 Entry ID:23049501   Date:2012-09-03 
I regard this article....as helpfulas not helpful                                 






























related links
What are the requirements for usi ...
What is multicomputing mode and w ...
Manual Part B8 CP 343-1 Lean
Manual Part B3A CP 343-1 Advanced
How many communication instances ...
mySupport
My Documentation Manager 
Newsletter 
CAx-Download-Manager 
Support Request
To this entry
Print
Create PDF 
Send to a friend
QuickLinks
Compatibility tool 
Help
Online Help
Guided Tour