ProTool -- Working with projects -- Upgrading to new version
How do you migrate a ProTool project with SIMOTION CPU connection to a WinCC flexible project and SIMOTION SCOUT?
Which version of Image of the relevant operator panels can be used for the corresponding version of ProTool?
Converting old configurations to Runtime - Procedure for ProTool versions prior to V6.0
Open Pro Tool 1.x configuration with current software
Which device is a suitable replacement for an OP25?
What solution can be offered for a defective MP40/C36A?
What changes do you have to make in the configuration after replacing the OP/TP 25/35 by an OP/TP 27/37 in a connection with the SIMATIC S5 via PROFIBUS DP?
What changes are necessary when a WF470 is replaced by an MP270 Touch in an S5 controller?
What changes are necessary when a WF470 is replaced by an MP270 Touch in an S5 controller?
Part number:

Configuration Notes:

  • The blocks used for WF470 must be removed completely.
  • The pictures and functions configured for WF470 cannot be migrated and must be created anew for the MP270.
  • The MP270 can be connected to the AS511 without any additional blocks in the S5.

Note:
In the case of SIMATIC S5 PLCs it is also possible to make the connection to the multipanel MP270 also via the PROFIBUS interface module IM308C.
In the S5 you need driver blocks.