DescriptionThe following tables give you the space requirements for the SIMATIC PCS 7 V6.0 standard blocks and templates.
Function block
Instance-specific CODE memory Space in bytes
Instance-specific DATA memory Space in bytes
FB CODE memory Space in bytes
ADD4_P
FC256
64
0
132
ADD8_P
FC257
96
212
AVER_P
FB34
40
54
376
COUNT_P
FB36
348
CTRL_PID
FB61
604
6728
CTRL_S
FB76
644
9024
DEADT_P
FB37
126
712
DIF_P
FB38
72
510
DIG_MON
FB62
482
1686
DOSE
FB63
592
4496
ELAP_CNT
FB64
334
1094
FMCS_PID
FB114
772
6660
FMT_PID
FB77
856
6494
INT_P
FB40
84
876
INTERLOK
FB75
20
78
1162
LIMITS_P
FB41
58
224
MEANT_P
FB42
154
1314
MEAS_MON
FB65
1494
MESSAGE
FB43
278
692
MOT_REV
FB67
382
3784
MOT_SPED
FB68
4564
MOTOR
FB66
364
2142
MSG_NACK
FB78
274
740
MUL_R4
FC262
MUL_R8
FC263
OB1_TIME
FB69
70
1830
OP_A
FB45
56
164
OP_A_LIM
FB46
68
366
OP_A_RJC
FB47
396
OP_D
FB48
44
294
OP_D3
FB49
46
1144
OP_TRIG
FB50
174
POLYG_P
FC271
180
1186
PT1_P
FB51
66
346
R_TO_DW
FC282
272
RAMP_P
FB52
532
REC_BO
FB208
128
2364
REC_R
FB210
476
1340
SEND_BO
FB207
110
1676
SEND_R
FB209
478
3894
RATIO_P
FB70
134
892
SPLITR_P
FC272
654
SWIT_CNT
FB71
316
996
VAL_MOT
FB74
3790
VALVE
FB73
2736
Instance- specific CODE memory Space in bytes
FB DATA memory Space in bytes
Instance- specific DATA memory Space in bytes
CH_AI
FC 275
4492
530
CH_AO
FC 276
1344
764
CH_DI
FC 277
314
270
CH_DO
FC 278
286
CH_U_AI
FC 283
4736
714
CH_U_AO
FC 284
1436
912
CH_U_DI
FC 285
414
CH_U_DO
FC 286
434
IM_DRV
FB 90
10735
969
4290
MOD_1
FB 91
4846
448
326
MOD_2
FB 92
5396
422
MOD_D1
FB 93
10354
522
666
MOD_D2
FB 94
9266
1070
MOD_3
FB 95
4862
442
428
MOD_MS
FB 96
7126
720
MOD_HA
FB 97
3804
328
MOD_CP
FB 98
6458
516
320
MOD_PAL0
FB 99
4570
384
MOD_PAX0
FB 112
4476
DREP
FB 113
13984
782
DREP_L
FB 125
20506
1424
498
812
RCV_341
FB 121
9020
130
870
SND_341
FB 120
3924
284
P_RCV_RK
FB 122
2990
P_SND_RK
FB 123
100
MODB_341
FB 80
8186
630
OB_DIAG
FB 124
4658
903
80
OB_DIAG1
FB 118
7866
1048
308
DPAY_V0
FB 108
16609
1657
1680
DPAY_V1
FB 115
11193
1731
PADP_L00
FB 109
17896
1474
562
PADP_L01
FB 110
18842
878
PADP_L02
FB 111
20078
1252
PADP_L10
FB 116
18600
1740
526
PA_AI
FB 101
1726
228
PA_AO
FB 103
2672
PA_DI
FB 104
1466
198
PA_DO
FB 105
2446
220
PA_TOT
FB 102
1826
232
PO_UPDAT
FC 279
404
52
RACK
FB 107
8449
855
234
SUBNET
FB 106
4940
210
OB_BEGIN OB_END
FB 100 FC 280
22196
-
4632
CFC chart (Template) name
Anamon
6107
633
Cascade
13020
2922
Digmon
2126
370
Dose
10252
1188
676
DoseLiq
11510
1476
680
MotRev
4500
1588
386
MotSpeed
5280
Motor
2858
826
MotorI
3993
899
446
PidCtrl
13022
2082
674
Ratio
13558
6490
2006
SetPoint
1840
798
SplitRng
13671
2467
Valve
3452
Valve_1FB
874
ValveI
4581
1219
ValveM
4506