show the entry list
HMI accessories -- Product information -- Technical data and ordering information
Wich protective films can I use with SIMATIC HMI panels?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
How can you ensure full battery capacity of the Mobile Panel 277 (F) IWLAN even after a long period of time?
What are the order numbers for the backup batteries and accumulators for the operator panels?
Which protective covers are available for panels?
Box PC -- Setting up and parameterizing hardware -- Connecting devices
What do you need to watch out for when operating SIMATIC software on SIMATIC IPC227D and IPC277D?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Where do you find the slot number of a PCI slot in a SIMATIC PC?
How do you connect the PS Expansion Board of the CPU 41x-2 PCI V3.4 to the internal voltage supply of the Box PC 627?
Panel PC -- Setting up and parameterizing hardware -- Connecting devices
What are the order numbers of the back-up batteries for SIMATIC IPCs and SIMATIC Field PGs?
What do you need to watch out for when operating SIMATIC software on SIMATIC IPC227D and IPC277D?
Why is the UPS not recognized via USB interface when a Panel PC 477-HMI or -HMI/RTX is operating with a SITOP DC UPS module?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Why should a SIMATIC PC not be switched on in the buffered UPS mode?
What must be considered when installing a SIMATIC Panel PC 477 (DC 24V version)?
Plug-in strips for Panel PCs
How do you connect the PS Expansion Board of the CPU 41x-2 PCI V3.4 to the internal voltage supply of the Box PC 627?
Can I use a keyboard with USB interface and internal USB hub for the SIMATIC Panel PCs 670 and 870?
C7 6xx -- Setting up and parameterizing hardware -- Connecting and wiring modules
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
C7-613: Power Supply of Digital Inputs
C7-633P: Suppressor Circuit of Current Inputs
Basic Panels -- Product information -- Technical data and ordering information
How do you load the 3D, CAx and ePLAN data for the SIMATIC products?
What support does Siemens AG offer to make use of WinCC flexible, WinCC flexible Runtime and panels that can be configured with WinCC flexible comply with FDA regulations?
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
Which SIMATIC Panels have the CCC certificate?
Wich protective films can I use with SIMATIC HMI panels?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
How can you determine the "E-Stand" (hardware release) of an operator panel?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
What connections are there between the version designations in WinCC flexible?
Which PROFINET services are supported by SIMATIC panels.
What are the functional differences between the different SIMATIC panels?
Why is an Open Source CD supplied with the operator panel?
What support does Siemens AG offer to make products comply with FDA regulations?
What support does Siemens AG offer to make use of WinCC Runtime Advanced, WinCC Runtime Professional and panels that can be configured with WinCC (TIA Portal) comply with FDA regulations?
Which panels are certified for shipbuilding?
What should you watch out with regard to licenses for WinCC flexible and panels?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Which Siemens department holds the EC conformity declarations for SIMATIC HMI?
Micro Panels -- Product information -- Technical data and ordering information
What support does Siemens AG offer to make use of WinCC flexible, WinCC flexible Runtime and panels that can be configured with WinCC flexible comply with FDA regulations?
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
What are the resolutions and mounting positions of the various HMI Panels and Panel PCs?
Wich protective films can I use with SIMATIC HMI panels?
What connections are there between the version designations in WinCC flexible?
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
What support does Siemens AG offer to make products comply with FDA regulations?
Which panels are certified for shipbuilding?
Which panels are certified for the FM explosion protection standard for North America?
What should you watch out with regard to licenses for WinCC flexible and panels?
Which Siemens department holds the EC conformity declarations for SIMATIC HMI?
Which panels and flat screens does Siemens currently offer for hazardous areas with potentially explosive atmosphere (Ex2/22)?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Which protective covers are available for panels?
Pushbutton Panels -- Product information -- Technical data and ordering information
How do you load the 3D, CAx and ePLAN data for the SIMATIC products?
What support does Siemens AG offer to make use of WinCC flexible, WinCC flexible Runtime and panels that can be configured with WinCC flexible comply with FDA regulations?
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
Which panels are certified for the FM explosion protection standard for North America?
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
Which panels and flat screens does Siemens currently offer for hazardous areas with potentially explosive atmosphere (Ex2/22)?
Which SIMATIC Panels have the CCC certificate?
How can you determine the "E-Stand" (hardware release) of an operator panel?
What connections are there between the version designations in WinCC flexible?
What support does Siemens AG offer to make products comply with FDA regulations?
What should you watch out with regard to licenses for WinCC flexible and panels?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Correction in the French manual for Push-button Panels PP7, PP17-I, PP17-II
Touch Panel / Operator Panel -- Product information -- Technical data and ordering information
What support does Siemens AG offer to make use of WinCC flexible, WinCC flexible Runtime and panels that can be configured with WinCC flexible comply with FDA regulations?
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
Which SIMATIC Panels have the CCC certificate?
Wich protective films can I use with SIMATIC HMI panels?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
How can you determine the "E-Stand" (hardware release) of an operator panel?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
Which PROFINET services are supported by SIMATIC panels.
Which panels and flat screens does Siemens currently offer for hazardous areas with potentially explosive atmosphere (Ex2/22)?
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
Why is an Open Source CD supplied with the operator panel?
Which panels does Siemens currently offer with stainless steel fronts (INOX)?
What support does Siemens AG offer to make products comply with FDA regulations?
What support does Siemens AG offer to make use of WinCC Runtime Advanced, WinCC Runtime Professional and panels that can be configured with WinCC (TIA Portal) comply with FDA regulations?
What are the order numbers for the backup batteries and accumulators for the operator panels?
Which panels are certified for shipbuilding?
Which panels are certified for the FM explosion protection standard for North America?
Which protective covers are available for panels?
Which Siemens department holds the EC conformity declarations for SIMATIC HMI?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Multi Panel -- Product information -- Technical data and ordering information
Which PROFINET services are supported by SIMATIC panels.
What support does Siemens AG offer to make use of WinCC flexible, WinCC flexible Runtime and panels that can be configured with WinCC flexible comply with FDA regulations?
What support does Siemens AG offer to make use of WinCC Runtime Advanced, WinCC Runtime Professional and panels that can be configured with WinCC (TIA Portal) comply with FDA regulations?
Which frame colors are used for the SIMATIC Panels and SIMATIC Panel PCs?
Which panels are certified for the FM explosion protection standard for North America?
How resistant to chemicals are the SIMATIC HMI operator panels and Industrial PCs?
Which panels and flat screens does Siemens currently offer for hazardous areas with potentially explosive atmosphere (Ex2/22)?
Wich protective films can I use with SIMATIC HMI panels?
How can you determine the "E-Stand" (hardware release) of an operator panel?
What is the power consumption or power dissipation of the SIMATIC HMI operator panels?
Where are the current declarations of conformity to be found for SIMATIC HMI panels (CE, UL, cUL, GOST)?
The C7 6xx complete devices are to be discontinued in October 2010 – what are their successors?
Which panels does Siemens currently offer with stainless steel fronts (INOX)?
What support does Siemens AG offer to make products comply with FDA regulations?
What are the order numbers for the backup batteries and accumulators for the operator panels?
Which panels are certified for shipbuilding?
How do you replace a faulty operator panel, or where can I have a faulty device repaired?
Different sized projects for MP270 devices
Which protective covers are available for panels?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Which SIMATIC Panels have the CCC certificate?
Which Siemens department holds the EC conformity declarations for SIMATIC HMI?
What options exist for ordering missing plug-in terminal strips for the power supply of panels?
Part number:

Description:

HMI Panels:
You can order 2-pin power supply connectors with order number "6AV6671-8XA00-0AX0".
The connectors fit all HMI panels except push button panels.
The package contains 10 power supply connectors with screw terminals.


Fig. 01

Alternatively, a number of electronics manufacturers provide suitable terminal strips.

Push Button Panels, PP7 / PP17-I  / PP17-II:
With order number "6AV3678-3XC30" you can order the service package for the Push Button Panels.
The service package comprises

  • 1x seal PP7
  • 1x seal PP17
  • 5x clamping blocks
  • 1x contact terminal strip PP7
  • 1x contact terminal strip PP17

Alternatively, a number of electronics manufacturers provide suitable terminal strips.

Note:
Below is a list of order numbers from CONRAD (www.conrad.de).
We cannot provide any guarantee for the validity of third-party order numbers, products and their functionality. These are manufacturer-related and might change in the course of time.

These connectors (6AV6671-8XA00-0AX0) can also be used in the following devices:

  • Box PCs
  • Panel PCs
  • Flat Panels

Power supply terminal strip:
 
HMI Panels: Order no. 731765: 2-pin, 5mm contact spacing
PP7: Order no. 729833: 2-pin, 3.5mm contact spacing
PP17 I / PP17 II: Order no. 729841: 3-pin, 3.5mm contact spacing

Keywords:
Connector, Push-on terminal strip, Contact terminal strip

 Entry ID:14353804   Date:2009-01-22 
I regard this article....as helpfulas not helpful                                 
mySupport
My Documentation Manager 
Newsletter 
CAx-Download-Manager 
Support Request
To this entry
Print
Create PDF 
Send to a friend
QuickLinks
Compatibility tool 
Topics
Help
Online Help
Guided Tour